Skip to content

Power Cables Product Feature Selector

Narrow Results

RoHS/ELV Compliance RoHS/ELV Compliance Explanation
Lead Free Solder Processes Lead Free Solder Processes Explanation
  • Not relevant for lead free process
  • Common to all 72 remaining products
Cable Jacket Material
Outside Diameter (mm) - Switch to in
Cable Jacket Color
Wire Diameter (mm) - Switch to in
Conductor O.D. (mm) - Switch to in
CMA (CMA)
Insulation
Voltage Rating (VAC)
Insulation Material
Brand
  • Raychem
  • Common to all 72 remaining products
Showing 1 - 20 of 72 Matching Products

Product Line Information

Previous Previous [1] 2 3 4 Next Next
Part Differing Features
No Image Available

  • Thermorad O Cable Jacket Material
  • Fuel and Oil Resistant Application
  • Wire Size (AWG/CM) = 0 AWG
  • 1045 Strands x 30 AWG
  • Outside Diameter = 14.22 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 14.22 mm
  • Conductor O.D. = 10.97 mm
  • CMA = 104500 CMA
  • Double Insulated
Not EU RoHS or ELV Compliant, Not applicable for solder process capability
No Image Available

  • Thermorad O Cable Jacket Material
  • Fuel and Oil Resistant Application
  • Wire Size (AWG/CM) = 00 AWG
  • 1330 Strands x 30 AWG
  • Outside Diameter = 15.65 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 15.65 mm
  • Conductor O.D. = 12.80 mm
  • CMA = 166500 CMA
  • Double Insulated
Not EU RoHS or ELV Compliant, Not applicable for solder process capability
Click here for product details for 10603-4-0

  • Thermorad O Cable Jacket Material
  • Fuel and Oil Resistant Application
  • Wire Size (AWG/CM) = 4 AWG
  • 133 Strands x 25 AWG
  • Outside Diameter = 9.65 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 9.65 mm
  • Conductor O.D. = 6.91 mm
  • CMA = 42615 CMA
  • Double Insulated
Not EU RoHS or ELV Compliant, Not applicable for solder process capability
Click here for product details for 10603-8-0

  • Thermorad O Cable Jacket Material
  • Fuel and Oil Resistant Application
  • Wire Size (AWG/CM) = 8 AWG
  • 133 Strands x 29 AWG
  • Outside Diameter = 7.11 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 7.11 mm
  • Conductor O.D. = 4.47 mm
  • CMA = 16983 CMA
  • Double Insulated
Not EU RoHS or ELV Compliant, Not applicable for solder process capability
Click here for product details for AFR35-16-0

  • Conductor Area = Cross-Section Area 16.0 mm²
  • Crosslinked Polyolefin Cable Jacket Material
  • Flexible Application
  • Outside Diameter = 8.10 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 8.10 mm
  • Conductor O.D. = 5.70 mm
  • CMA = 31357 CMA
  • Single Insulated
  • Voltage Rating = 1900 - 3300 VAC
Converted to EU RoHS/ELV Compliant, Not applicable for solder process capability
Click here for product details for FTR16-10-0

  • Conductor Area = Cross-Section Area 10.0 mm²
  • Thermorad Cable Jacket Material
  • Flexible Application
  • Outside Diameter = 7.40 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 7.40 mm
  • Conductor O.D. = 4.55 mm
  • CMA = 18848 CMA
  • Double Insulated
  • Voltage Rating = 600 - 1000 VAC
Always EU RoHS/ELV Compliant, Not applicable for solder process capability
Click here for product details for TR16-10-0

  • Conductor Area = Cross-Section Area 10.0 mm²
  • Thermorad Cable Jacket Material
  • Flexible Application
  • Outside Diameter = 6.20 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 6.20 mm
  • Conductor O.D. = 4.55 mm
  • CMA = 16983 CMA
  • Single Insulated
  • Voltage Rating = 600 VAC
Always EU RoHS/ELV Compliant, Not applicable for solder process capability
Click here for product details for TR16-16-0

  • Conductor Area = Cross-Section Area 16.0 mm²
  • Thermorad Cable Jacket Material
  • Flexible Application
  • Outside Diameter = 7.40 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 7.40 mm
  • Conductor O.D. = 5.51 mm
  • CMA = 26818 CMA
  • Single Insulated
  • Voltage Rating = 600 VAC
Always EU RoHS/ELV Compliant, Not applicable for solder process capability
Click here for product details for TR16-25-0

  • Conductor Area = Cross-Section Area 25.0 mm²
  • Thermorad Cable Jacket Material
  • Flexible Application
  • Outside Diameter = 9.30 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 9.30 mm
  • Conductor O.D. = 7.30 mm
  • CMA = 42615 CMA
  • Single Insulated
  • Voltage Rating = 600 VAC
Always EU RoHS/ELV Compliant, Not applicable for solder process capability
Click here for product details for TR16-35-0

  • Conductor Area = Cross-Section Area 35.0 mm²
  • Thermorad Cable Jacket Material
  • Flexible Application
  • Outside Diameter = 10.60 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 10.60 mm
  • Conductor O.D. = 8.55 mm
  • CMA = 66500 CMA
  • Single Insulated
  • Voltage Rating = 600 VAC
Always EU RoHS/ELV Compliant, Not applicable for solder process capability
Click here for product details for TR16-4-0

  • Conductor Area = Cross-Section Area 4.0 mm²
  • Thermorad Cable Jacket Material
  • Flexible Application
  • Outside Diameter = 4.50 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 4.50 mm
  • Conductor O.D. = 2.90 mm
  • CMA = 9354 CMA
  • Single Insulated
  • Voltage Rating = 600 VAC
Always EU RoHS/ELV Compliant, Not applicable for solder process capability
Click here for product details for TR16-50-0

  • Conductor Area = Cross-Section Area 50.0 mm²
  • Thermorad Cable Jacket Material
  • Flexible Application
  • Outside Diameter = 12.50 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 12.50 mm
  • Conductor O.D. = 10.15 mm
  • CMA = 104500 CMA
  • Single Insulated
  • Voltage Rating = 600 VAC
Always EU RoHS/ELV Compliant, Not applicable for solder process capability
Click here for product details for TR16-6-0

  • Conductor Area = Cross-Section Area 6.0 mm²
  • Thermorad Cable Jacket Material
  • Flexible Application
  • Outside Diameter = 5.21 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 5.20 mm
  • Conductor O.D. = 3.60 mm
  • CMA = 16983 CMA
  • Single Insulated
  • Voltage Rating = 600 VAC
Always EU RoHS/ELV Compliant, Not applicable for solder process capability
Click here for product details for TR16-70-0

  • Conductor Area = Cross-Section Area 70.0 mm²
  • Thermorad Cable Jacket Material
  • Flexible Application
  • Outside Diameter = 14.60 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 14.60 mm
  • Conductor O.D. = 12.00 mm
  • CMA = 133000 CMA
  • Single Insulated
  • Voltage Rating = 600 VAC
Always EU RoHS/ELV Compliant, Not applicable for solder process capability
Click here for product details for ZHI15-10-0

  • Conductor Area = Cross-Section Area 10.0 mm²
  • Zerohal Cable Jacket Material
  • Fire Safety Application
  • Outside Diameter = 8.20 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 8.20 mm
  • Conductor O.D. = 4.60 mm
  • CMA = 16983 CMA
  • Double Insulated
  • Voltage Rating = 600 - 1000 VAC
Always EU RoHS/ELV Compliant, Not applicable for solder process capability
Click here for product details for ZHI15-25-0

  • Conductor Area = Cross-Section Area 25.0 mm²
  • Zerohal Cable Jacket Material
  • Fire Safety Application
  • Outside Diameter = 10.90 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 10.90 mm
  • Conductor O.D. = 7.20 mm
  • CMA = 42615 CMA
  • Double Insulated
  • Voltage Rating = 600 - 1000 VAC
Always EU RoHS/ELV Compliant, Not applicable for solder process capability
Click here for product details for ZHI15-50-0

  • Conductor Area = Cross-Section Area 50.0 mm²
  • Zerohal Cable Jacket Material
  • Fire Safety Application
  • Outside Diameter = 14.70 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 14.70 mm
  • Conductor O.D. = 10.30 mm
  • CMA = 104500 CMA
  • Double Insulated
  • Voltage Rating = 600 - 1000 VAC
Always EU RoHS/ELV Compliant, Not applicable for solder process capability
Click here for product details for ZHI15-6-0

  • Conductor Area = Cross-Section Area 6.0 mm²
  • Zerohal Cable Jacket Material
  • Fire Safety Application
  • Outside Diameter = 6.17 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 6.16 mm
  • Conductor O.D. = 2.96 mm
  • CMA = 9354 CMA
  • Double Insulated
  • Voltage Rating = 600 - 1000 VAC
Always EU RoHS/ELV Compliant, Not applicable for solder process capability
No Image Available

  • Thermorad O Cable Jacket Material
  • Fuel and Oil Resistant Application
  • Wire Size (AWG/CM) = 2 AWG
  • 665 Strands x 30 AWG
  • Outside Diameter = 11.84 mm
  • Cable Jacket Color = Black
  • Wire Diameter = 11.84 mm
  • Conductor O.D. = 8.76 mm
  • CMA = 66500 CMA
  • Double Insulated
Not EU RoHS or ELV Compliant, Not applicable for solder process capability
No Image Available

  • Modified Fluoropolymer Cable Jacket Material
  • Flexible Application
  • Wire Size (AWG/CM) = 0 AWG
  • 2660 Strands x 34 AWG
  • Outside Diameter = 14.17 mm
  • Cable Jacket Color = White
  • Wire Diameter = 14.17 mm
  • Conductor O.D. = 11.43 mm
  • CMA = 133000 CMA
  • Double Insulated
Always EU RoHS/ELV Compliant, Not applicable for solder process capability
Showing 1 - 20 of 72 Matching Products

Product Line Information

Previous Previous [1] 2 3 4 Next Next
Bookmark and Share
This list is temporary. The list will not be viewable on another computer and will be deleted within 30 days.

If your browser cookies are cleared, your temporary list will be lost. You can save this list and get all of the My Part List features by becoming a registered user of the Tyco Electronics web site.